12/24/40.5kV Panno Asanble ak anklanchman
Shutter Assembly 5GP.320.010 Dyagram Enstalasyon
(800mm lajè mitan-mete switchgear)
Shutter Assembly 5GP.320.010 Lis Aranjman
Non. | Non | Desen non. | Kte.(pc/ansanm) |
1 | Dwa sipò sipò | 8GP.123.011 | 1 |
2 | Plak koneksyon dwat | 5GP.235.011 | 1 |
3 | Ki endike tag | 8GP.866.014 | 1 |
4 | Koneksyon gòch | 5GP.235.010 | 1 |
5 | Support sipò gòch | 8GP.123.010 | 1 |
6 | Koneksyon soude | 5GP.174.016.1(Pou VD4) | 2 |
5GP.174.016.2(Pou GPVN) | |||
5GP.174.016.3(Pou VB2) | |||
7 | Desann pòtay vole | 8GP.320.010 | 1 |
8 | Blòk bloke 8 | PK-8 | 8 |
9 | Plak bracket | 8GP.123.013 | 3 |
Non. | Non | Desen non. | Kte.(pc/ansanm) |
10 | Koneksyon soude | 5GP.174.017.1(Pou VD4, 40kA) | 2 |
5GP.174.017.2(Pou VD4, 31.5kA) | |||
5GP.174.017.3(Pou GPPN) | |||
5GP.174.017.4(Pou VB2) | |||
11 | Ki endike tag | 8GP.866.012 | 1 |
12 | Ki endike tag | 8GP.866.013 | 2 |
13 | Plak bracket | 8GP.123.012 | 3 |
14 | Upper vole | 8GP.320.011 | 1 |
15 | Gid baton | 8GP.234.011(Pou VD4, GPVN) | 2 |
8GP.234.011.1(Pou VB2) | |||
16 | Manch bouchon | 8GP.210.011 | 2 |
Lòt spesifikasyon lis aranjman vole
Kòd | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
Lajè kabinè | 650mm | 700mm | 840mm | 900mm | 1000mm |
Pòtay anwo | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
Desann pòtay | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
Panno Asanble 5GP.320.011
(1000mm lajè switchgey nan mitan yo)
Shutter Mechanism Device 5GP.320.011 Lis Aranjman
(1000mm lajè switchgey nan mitan yo)
Non. | Non | Desen non. | Kte.(pc/ansanm) |
1 | Dwa sipò sipò | 8GP.123.276 | 1 |
2 | Plak koneksyon dwat | 5GP.235.012 | 1 |
3 | Ki endike tag | 8GP.866.014 | 1 |
4 | Plak koneksyon gòch | 5GP.235.013 | 1 |
5 | Support sipò gòch | 8GP.123.275 | 1 |
6 | Koneksyon soude asanble | 5GP.174.281 | 2 |
7 | Desann vole | 8GP.320.273 | 1 |
8 | Blòk bloke 10 | PK-10 | 8 |
Non. | Non | Desen non. | Kte.(pc/ansanm) |
9 | Plak bracket | 8GP.123.278 | 3 |
10 | Koneksyon soude jwenti | 5GP.174.282 | 2 |
11 | Ki endike tag | 8GP.866.012 | 1 |
12 | Ki endike tag | 8GP.866.013 | 2 |
13 | Plak bracket | 8GP.123.277 | 3 |
14 | Upper vole | 8GP.320.274 | 1 |
15 | Gid baton | 8GP.234.272 | 2 |
16 | Manch bouchon | 8GP.210.011 | 2 |
Lòt spesifikasyon lis aranjman vole
Kòd | 5GP.320.011.1 | 5GP.320.011/JY | 5GP.320.011.2 | 5GP.320.011.3 |
Lajè kabinè | 800mm | 1000mm (Izolan) | 1100mm | 1200mm |
Pòtay anwo | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
Desann pòtay | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Nòt: 5GP.320.275 se pou isolation vole pa plak SMC nan mitan ak tou de fini pa fe plat, lòt vole asanble si bezwen isolation pòtay souple spécifier.
Tè switch operasyon mekanis aparèy verrouillage (Pou koneksyon bra kondwi operasyon) 5GP.363.010.1 dyagram asanble
Enstriksyon nan aparèy Interlock
Se aparèy la verrouillage te ajoute verrouillage la ranvèse ak pòt la dèyè ki fèt sou baz la nan orijinal 5GP.363.010 latè switch operasyon mekanis aparèy verrouillage.Sa vle di, apre switch la tè fèmen epi louvri pòt la dèyè (plak sele), verrouillage orijinal la te kapab toujou opere switch la tè, men verrouillage sa a pa t 'kapab.Ou dwe premye fèmen pòt la dèyè (plak sele) yo nan lòd yo opere switch la tè a.
Prensip yo k ap travay nan aparèy la verrouillage se chanje manch rad la fèmen nimewo 24 nan sa ki te montre sou bò dwat ak te ajoute sezon prentan sou baz orijinal la 5GP .363.010.Lè pòt la dèyè (plak sele) louvri, manch rad fèmen a antre nan twou kare kabinè a (rekòmande gwosè 35X35), switch tè pa ka opere.
Mekanis operasyon switch tè aparèy verrouillage (Pou operasyon kondwi bra koneksyon)
5GP.363.010.1 lis aranjman.
Non. | Non | Desen non. | Kte.(pc/ansanm) |
1 | Portant | 8GP.263.011 | 1 |
2 | Sektè | 8GP.192.010 | 1 |
3 | Sektè | 8GP.192.011 | 1 |
4 | Manch aks | 8GP.210.014.1 | 2 |
5 | Sektè | 8GP.151.041 | 1 |
6 | Manch aks | 8GP.211.061 | 1 |
7 | Sektè | 8GP.151.039 | 1 |
8 | Manch aks | 8GP.211.062 | 1 |
9 | Boulon M5 × 12 | GB70-85 | 1 |
10 | Sektè | 8GP.151.042 | 1 |
11 | Sektè | 8GP.151.043 | 1 |
12 | Baton operasyon | 8GP.200.013.1 (Long 1432 pou pwofondè kabinè 1500 pwofondè) | 1 |
8GP.200.013.2 (Long 1590 pou pwofondè kabinè 1660) | 1 | ||
13 | Sipòte plak | 8GP.161.058 | 1 |
8GP.161.058.1(Pou opsyon) | 1 |
Non. | Non | Desen non. | Kte.(pc/ansanm) |
14 | Kouvri | 8GP.017.011.1 | 1 |
15 | Support | 5GP.043.022 | 1 |
16 | Sipòte plak | 8GP.161.059 | 1 |
17 | Kurseur | 8GP.143.010 | 2 |
18 | Manch aks | 8GP.211.058 | 1 |
19 | Manch bouchon | 8GP.211.057 | 3 |
20 | Sipò baz | 8GP.043.019 | 1 |
21 | Fèmen ki endike | 8GP.866.010 | 1 |
22 | Koneksyon baton asanble | 5GP.233.030.1 | 1 |
5GP.233.030.3(Pou opsyon) | 1 | ||
23 | Louvri ki endike | 8GP.866.011 | 1 |
24 | Bloke manch rad | 8GP.211.201 | 1 |
25 | Plak ploge dan | 8GP.151.044 | 1 |
26 | Manch aks | 8GP.211.060 | 2 |
27 | Tag | 8GP.860.010 | 1 |
28 | Prentan presyon | 8GP.282.201 | 1 |
29 | Bloke manch fikse boulon | 8GP.920.002 | 1 |
Remak:
1. Nimewo 1 ~ 12 gade paj anvan an.
2. No 22 Koneksyon baton asanble, bra a koneksyon gen de gwosè: Kabinè sant distans 60mm an komen.Si bezwen 80mm distans sant tanpri tcheke paj 17 enstriksyon asanble bra koneksyon an, epi presize lè kòmann-nan.
Tè switch operasyon mekanis aparèy verrouillage (Pou operasyon kondwi bizote) 5GP.577.1001
Tè switch operasyon mekanis aparèy verrouillage (Pou operasyon kondwi bizote) 5GP.577.1001 lis aranjman
Non. | Non | Desen non. | Kte.(pc/ansanm) |
1 | Portant | 8GP.263.011 | 1 |
2 | Plak bouchon | 8GP.151.084 | 2 |
3 | Manch aks | 8GP.210.014.1 | 2 |
4 | Sektè | 8GP.151.041 | 1 |
5 | Manch aks | 8GP.210.014.2 | 1 |
6 | Boulon M 5X12 | GB70-85 | 1 |
7 | Sektè | 8GP.151.042 | 1 |
8 | Sektè | 8GP.151.043 | 1 |
9 | Manch aks | 8GP.210.014.3 | 1 |
Non. | Non | Desen non. | Kte.(pc/ansanm) |
10 | Manch bouchon | 8GP.210.322 | 1 |
11 | Baton operasyon | 8GP.174.214 | 1 |
12 | Kouvri | 8GP.017.011.2 | 1 |
13 | Sipò baz | 5GP.043.022 | 1 |
14 | Kurseur | 8GP.143.010 | 2 |
15 | Sipòte plak | 8GP.161.059 | 1 |
16 | Sipòte plak | 8GP.161.058 | 1 |
17 | Plak ploge dan | 8GP.151.044 | 1 |
18 | Tag | 8GP.860.010 | 1 |
Remak: 1. Mekanis sa a bezwen anklanche ak desann pòt, tanpri presize lè kòmann-nan.